    Product Details:

    Place of Origin: China
    Brand Name: Topband
    Certification: MSDS
    Model Number: TB48100F-T110C

    Payment & Shipping Terms:

    Minimum Order Quantity: 100
    Price: Negotiable
    Packaging Details: standard export carton
    Delivery Time: 2~4weeks for samples; 4~6weeks for mass production
    Payment Terms: L/C, T/T
    Supply Ability: 450Mwh/year
    Contact Now
    Detailed Product Description
    Battery Type: LiFePO4 Colar: Black
    Rated Voltage: 51.2V Capacity: 100Ah

    LiFePO4 Telecom Battery 48V100Ah 4U or 5U Rack , 100A Discharge , Long Lifecycle

     

    LiFePO4 Telecom Battery 48V100Ah 4U or 5U Rack , 100A Discharge Long Lifecycle

    1. General Information

    This specification defines the performance of rechargeable LiFePO4 battery pack TB48100F -T105C manufactured by TOPBAND NEW ENERGY CO.,LTD, describes the type, performance, technical characteristics, warning and caution of the battery pack.

    2. Battery Specification(@ 25±5℃)

    NO Items Characteristics
    2.1 Normal capacity 100Ah
    2.2 Nominal energy 4.8 KWh (15S);5.12KWh(16S)
    2.3 Nominal voltage 51.2V (LFP-16S)
    2.4 Internal resistance ≤40mΩ @1kHz AC
    2.5 Normal charge voltage 54.7±0.3V(15S );58.4±0.3V(16S)
    2.6 Float charge voltage(for Standby use) 51.75±0.3V (15S);55.2±0.3V(16S)
    2.7 Allowed MAX charge current 100A
    2.8 Charging limit current (optional) 10A
    2.9 Recommended charge current ≤50A
    2.10 Allowed MAX discharge current 100A
    2.11 End of discharge voltage 37.5V (15S) 40V(16S)
    2.12 Dimension Length 482±2 mm
    Depth 570±10mm
    height 176±2 mm
    2.13 Weight Approx. 59kg
    2.14 Operation temperature Charge 0~45℃
    Discharge -20~60℃
    2.15

     

    Self-discharge rate

    Residual capacity ≤2%/Month; ≤10%/ year
    Recover capacity ≤1%/Month; ≤6%/ year
    2.16 Storage environment ≤1month -20~+35℃,45~75%RH
    ≥3month -10~+35℃,45~75%RH
    Recommend environment 15~30℃,45~75%RH
     

     

    3. Electrical Characteristics & Test Condition

    Testing Conditions: Ambient Temperature: 25±5℃; Huminity:45%~75%.

    Normal charge:Charge battery under CC(0.33C)/CV(58.4V) mode until over charge protection or the charge current reduce to 0.05C, and then rest for 1h.

     

    NO Items Criterion Condition
    3.1 Normal Capacity 100Ah After Normal charge, discharge @0.33C current to the end of discharge voltage.
    3.2 Internal Impedance ≤40mΩ @50% SOC @1kHz AC internal resistance test instrument.
    3.3 Short circuit protection Auto cutoff load when short circuit Connect the positive and negative of this battery pack through a lead with 0.1Ω resistance.
    3.4 Cycle life @DOD100% ≥2000 cycles After Normal charge,discharge @0.33C current to the end of discharge voltage. Repeat above process until discharge capacity reduce to 80% of initial value.
    3.5

    @0.33C

    Discharge temperature

    characteristic@0.33C

    -20℃ ≥70%

     

    Capacity @specified temperature

    LiFePO4 Telecom Battery 48V100Ah 4U or 5U Rack , 100A Discharge Long LifecycleCapacity @ 25℃

     

    -0℃ ≥80%
    25℃ ≥100%
    55℃ ≥95%
    3.6 Capacity retention rate

    remain capacity

    ≥96%

    After normal charge, store the battery @25±5℃ for 28days, then discharge capacity @0.33C,the retention capacity accord with criterion.
     

    4. Circuit Protection

    The batteries are supplied with a LiFePO4 Battery Management System (BMS)that can monitor and optimized each single prismatic cell during charge & discharge, to protect the battery pack overcharge, over discharge, short circuit. Overall, the BMS helps to ensure safe and accurate running.

     

    No Item Content Criterion
    4.1 Over charge Over-charge warning for each cell 3.60±0.03V
    Over-charge protection for each cell 3.80±0.03V
    Over-charge release for each cell 3.38±0.05V
    Over-charge release method Under the release voltage
    4.2 Over discharge Over-discharge warning for each cell 2.80±0.05V
    Over-discharge protection each cell 2.50±0.05V
    Over-discharge release for each cell 2.90±0.10V
    Over-discharge release method Charging
    4.3 Over current Charge over current warning 105±3A
    Charge over current protection 110A±3A
    Charge over current release Discharge or auto release after 1min
    Discharge over current warning 105±3A
    Discharge over current protection 110A±3A
    Discharge over current release Charge or auto release after 1min
    Short circuit protection Available
    4.4 Temperature Charge over temperature protection Protect@55±3℃; Release@50±3℃;
    Charge under temperature protection Protect@0±3℃; Release@5±3℃
    Discharge over temperature protection Protect@65±3℃; Release@60±3℃;
    Discharge under temperature protection Protect@-20±3℃; Release@-15±3℃;
     

     

    5. User guide

    5.1 TB48XXF-T110X Operation principle and Wiring hint

    Input 220Vac, after rectification power module, output 48V. When the power grid normal, the battery will supply power according to system requirement, and to be charged at same time; when power off, the battery will supply energy, to make sure the DC power system working normally, to realize uninterruptible power supply. The power supply has second disconnection function, when the battery voltage is low, the battery output would be cut off to protect battery life.

    LiFePO4 Telecom Battery 48V100Ah 4U or 5U Rack , 100A Discharge Long Lifecycle

     

    5.2 Operation panel direction(TB48XX Series general reference)

    LiFePO4 Telecom Battery 48V100Ah 4U or 5U Rack , 100A Discharge Long Lifecycle

    Reset RS485 RS232 Dial switch RUN LED alarm LED SOC LED

     

    5.3 sleep mode

    The system would go into low-consumption mode in any of the following conditions:

    1. Single module or the whole system over discharge protection not recovered in 30s
    2. Press the keys for 3s
    1. The minimum single voltage lower than sleep voltage, and the lasting time reach sleep delay time( no communication, no protection, no balance, no current at same time).
    2. Standby more than 24h( no communication, no charge or discharge, no AC input).
    3. Force shutdown through upper-computer software.

    Before sleep mode, please make sure there is no input voltage, otherwise it can no go to sleep mode.

    5.4 wake up

    1. Connect to charger, and the charger output is more than 48V.
    2. Press the keys for 3s;
    3. Connect to communication cable, open upper computer software( if it goes to sleep mode due to over discharge protection, this method would not wake up the circuit board).

    Remark: single model or the whole system goes to low-consumption mode after over discharge protection, it would be wake-up every 4hs, to open discharge MOS. If it can be charged, it would exit sleep mode and start normal charge; if it fails to be charged after 10times of wake-up automatically, there would be no automatic wake-up.

     

    5.5 Installation drawing

    Case dimension: 482(Width) * 570(Depth) * 176(height) mm;

    Handle Depth:35mm; weight:Approx.59kg.