Home ProductsLithium Iron Phosphate Battery

22Ah / 24Ah Lithium Iron Phosphate Battery OEM / ODM Available

Good quality Deep Cycle Lithium Battery for sales
Good quality Deep Cycle Lithium Battery for sales
We have cooperated with Topband for several years, we think Topband is a reliable supplier with quality products, and professional technical support!

—— Stephan Moberg

In energy storage system project, Topband team provides expertise support and excellent product at reasonable price. Much appreciated for their effort

—— Christin Gartner

I'm Online Chat Now

22Ah / 24Ah Lithium Iron Phosphate Battery OEM / ODM Available

China 22Ah / 24Ah Lithium Iron Phosphate Battery OEM / ODM Available supplier
22Ah / 24Ah Lithium Iron Phosphate Battery OEM / ODM Available supplier 22Ah / 24Ah Lithium Iron Phosphate Battery OEM / ODM Available supplier

Large Image :  22Ah / 24Ah Lithium Iron Phosphate Battery OEM / ODM Available

Product Details:

Place of Origin: China
Brand Name: Topband
Certification: MSDS, UL
Model Number: TB1224F-S112B_00

Payment & Shipping Terms:

Minimum Order Quantity: 50
Price: Negotiable
Packaging Details: standard export carton
Delivery Time: 2~4weeks for samples; 4~6weeks for mass production
Payment Terms: L/C, T/T
Supply Ability: 450Mwh/year
Contact Now
Detailed Product Description
Nominal Voltage: 12.8V Typical Capacity: 24Ah
Energy: 307.2Wh Internal Resistance: ≤50mΩ
Discharge Cut-off Voltage: 8.0V Weight: 3.1kg
Dimension: 180*166*76mm Meterial: LiFePO4
Operating Temperature: -20~60℃ Cycle Life: ≥2000 (DOD100%)
Warranty: 2 Years Max. Continuous Discharge Current: 30A

12V 22ah / 24Ah Lithium Iron Phosphate Battery for Golf Trolley , Portable Power , LED

 

 

This specification applies to the TB1224F-S112B battery manufactured by SHENZHEN TOPBAND CO.,LTD,Describes the type and size,performance,technical characteristics,warning and caution of the rechargeable cell.

 

1. Battery Pack Brief Introduction

 

11 Battery Type

LiFePO4 (LFP)

 

1. 2 Reference Standard

1.3 Product SPEC

12V/24Ah 4S2P

 

14 Cell Brand and Model

TB1865135C-Fe-12Ah

 

15 Period of Warranty

24 Months from the date of shipment

 

16 Battery Specification Amendment

If the raw materials, production processing, production system or battery usage environments & other conditions need to be change, the amendment side needs provide the written advice to the other side, only the both sides come to an end, the amendment will be effective.

 

2 Battery Pack Basic Features

NO. Items Characteristics Testing Methods
1 Nominal Voltage 12V Follow
2 Nominal Capacity 24Ah Follow
3 Minimum Capacity 22.4Ah Follow
4 Battery internal Impedance Internal Impedance≤50mΩ, Internal Impedance Testing Machine
5 Shipment Voltage 12.8-13.6V Multi-meter
6 Dimension Length Approx 180mm

 

Venire caliper

Width Approx 166mm
Height Approx:76mm
gross weight Approx 3.1kg electronic scale
7 Working Temperature Charge 0~45℃,45~85%RH Temperature & Humidity Instruments
Discharge -20~55℃,45~85%RH
8 Storage Temperature & Humidity Range Short: above one month -20~+55℃,45~85%RH Temperature & Humidity Instruments
Medium: above three months 0~+45℃,45~85%RH
Long:above one year +5~+30℃,45~85%RH
9 Allowed maximum continuous charge current 20A Multi-meter
10 Allowed maximum continuous discharge current 30A Multi-meter
11 Allowed maximum reverse charge voltage NO Allowed /
12

Allowed m

ximum cha

ge voltage

14.6±0.1V Multi-meter
13 Discharge cut-off voltage 10±0.1V Multi-meter
 

3. Battery Pack Electrical Characteristics

3.1 Testing Conditions (Unless Specially Requirements)

Temperature:20±5℃ Related Humidity: 45~75%

Atmosphere Pressure: 86~106kPa

The testing items under the Shipment Voltage(12.8-13.6V )

 

3.2 Battery Pack Electrical Characteristics

No. Items Standards Testing Methods
1 Internal Impedance Impedance ≤50mΩ Under 20±5℃ Environment Temperature , the Usage Frequency of Fully Charge( 1KHz) , Use AC Internal Impedance test machine to test.
2 Nominal Capacity 24Ah Rest for 0.5~1 hour after fully charge, Using electrical loader to connect with the battery output port, and discharge with constant current 0.2C till it can’t discharge. Do the cycle three times, if there is one time that the discharge time is equal or more than 285minute, you can stop.
3 Short circuit protection No load ability after short-circuit .comeback capability of loading after remove the lead away, Short the pack with the lead (<50mΩ). If remove the lead away, connect the electronic loader with P+, P- of protection board again, so load ability comes back.
4 Allowed Maximum continuous charge Current 20A charging with 20A for more than 0.5h and the added temperature of battery pack less than 20℃.
5 Allowed Maximum continuous discharge Current 30A Discharging with 30A for more than 0.5h and the added temperature of battery pack less than 20℃.
 

 

6 Over Current Protection 80-110A Using electron load connect with output side, discharge with 80A for about 2sec Discharge with 110A for less than 20 millisecond,
7 the delay time of over current protection 10.0-100.0ms Using electron load connect with output side, discharge with more than 110A and record the voltage wave of output side with oscillograph . Numerating the time of voltage from wave to zero for voltage
7 cycle life Discharge Capacity ≥80% Discharge it with the current of 30A to the cut-off voltage, and store it for 15min.Charge a battery with the current of 30A, then keep the voltage and current constant and continue to charge it until completed . After storing the battery for 15min. The test is to be conducted as per the above cycles. The cycle should be 1000 times. At the 1001 times discharge capacity should not be less than ≥48Ah with 20A.
8 Discharge Temperature Characteristics The ratio between discharge capacity and charge capacity should be not less than the following value At 20±5℃ discharge the battery with the current of20A to the cut-off voltage and record charge capacity. Store the battery at the following temperature for 2h and discharge the battery with 20A to the cut-off voltage.
Discharge Current Discharge Temperature
-20℃ 0℃ 25℃ 55℃
0.2C 60% 80% 100% 95%
9 Charge Retention remain capacity≥90% At 20±5℃ completely charge and store it for 28days,and then discharge it with 20A to the cut-off voltage. (We suggest charge the battery to 12.8-13.6V every three months)
10 Over Discharge Protection furbish Charging With20A Charge the battery with 20A for 5min and measure the output voltage (≥10V)of the battery pack. The battery should have load .

 

4. Battery Pack Reliability Test

4.1 Testing condition (Unless Special Requirements)

Temperature:20±5℃ Relative Humidity: 45~75%

Atmosphere Pressure: 86~106kPa

All testing under full capacity(13.2-13.6V)

 

4.2 Reliability Test

No. Items Standards Testing Methods  
1 Vibration Testing The appearance of battery should not leakage, break or explosion Fix a charged battery on a vibrating table, vibrate it for 90 minutes in three mutually perpendicular directions at the 0.8mm resonance. The frequency is to be varied at the rate of 1hz/min between 10 and 55 hertz.  
2 High Temperature Discharge Testing The battery should be no remarkable breakage, distortion. Discharge time should not less than 255mins Place a full charged battery under the environments of 55℃ for 2 hours. Discharge it at the current of 200mA to the cut-off voltage. Then keep it at 20℃±5℃ for 2 hours.  
3 Low Temperature Discharge Testing The battery should be no remarkable breakage, distortion. Discharge time should not less than 180 minute Place a full charged battery under the environments of -20℃ for 15-24 hours. Discharge it at the current of 200mA to the cut-off voltage. Then keep it at 20℃±5℃ for 2 hours.  
4 Constant Humidity & Temperature Testing The battery should be no remarkable breakage, distortion. Discharge time should not less than180mins Place a full charged battery under the environments of 40℃ and 90% - 95%RH for 48 hours. And keep it in the room temperature for 2 hours. Then discharge it at the current of 200mA to the cut-off voltage.
5 High & Low Temperature Storage The battery should be no remarkable breakage, distortion. And charge/discharge normally Place a full charged battery in a oven with 55±2℃ for2 hours, then keep it under 20±5℃ for 4hrs, then place it in a oven with -20±2℃ for 2 hours, then keep for 4 hours under 20±5℃, cycle as high temperature-normal temperature-low temperature-normal temperature-high temperature for 10 times
 

5. BATTERY PACK SAFETY TEST

5.1 Testing condition (Unless Special Requirements)

Temperature:20±5℃ Relative Humidity: 45~75%

Atmosphere Pressure: 86~106kPa

All testing under full capacity(13.2-13.6V)

 

5.2 Battery Pack Safety Test

No. Items Standards Testing Methods
1 Short-Circuit The battery should be no remarkable breakage, distortion. And charge normally. Use a resistor with less than 0.05Ω to make the battery short circuit for 1 hour. The appearance and characteristics are normal.
2 Over Discharge Protection Test The battery should be no remarkable breakage, distortion. Appearance and charge are normal. Discharge the battery at the rate of 20A with the load of 30Ω for 24h . Charging for 10sec with specified adapter , and check the voltage(≥8.0V)
3 Impact Test The battery should be no explosion or catch fire Place a full charged battery on a flat and put a stainless steel stick (Diamond 7.9mm) in the middle of the battery upright . Beat the steel stick with 9.1Kg
 

6. Pack diagram

22Ah / 24Ah Lithium Iron Phosphate Battery OEM / ODM Available

 