Home ProductsRechargeable Lifepo4 Battery

Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh

Good quality Deep Cycle Lithium Battery for sales
Good quality Deep Cycle Lithium Battery for sales
We have cooperated with Topband for several years, we think Topband is a reliable supplier with quality products, and professional technical support!

—— Stephan Moberg

In energy storage system project, Topband team provides expertise support and excellent product at reasonable price. Much appreciated for their effort

—— Christin Gartner

I'm Online Chat Now

Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh

China Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh supplier
Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh supplier Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh supplier

Large Image :  Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh

Product Details:

Place of Origin: China
Brand Name: Topband
Certification: MSDS
Model Number: 18650AN-1500mAh

Payment & Shipping Terms:

Minimum Order Quantity: 3000pcs
Price: Negotiable
Packaging Details: standard export carton & pallet
Delivery Time: 2~4weeks for samples; 4~6weeks for mass production
Payment Terms: T/T, L/C
Supply Ability: 450Mwh/year
Contact Now
Detailed Product Description
Chemistry: NMC Norminal Voltage: 3.7V
Weight: ≤44g Nominal Capacity: 1500mAh@0.2C
Max Continue Discharge Current: (20A) 25℃(for Cycle Life)

  1. Preface 

 

This specification describes the type and dimension, performance, technical characteristics, warning and caution of the lithium ion rechargeable cell. The specification only applies to 18650AN-1500mAh cells supplied by TOPBAND New Energy Company.

 

  1. Definition 

 

  1. Nominal capacity

 

Nominal capacity is the initial discharge capacity of the cell, which is measured with discharge current of 300mA with 2.75V cut-off at 25℃ within 1hour after the standard charge.

Nominal capacity≥1500mAh

 

  1. Standard charge method

Under 25±2℃, it can be charged to 4.2V with constant current of 0.5C(750mA), and then, charged continuously with constant voltage of 4.2V until the charged current is 0.02C(30mA).

 

  1. Cell type and dimension 
    1. Description and model
    2. Description: Cylindrical Li-ion rechargeable cell
    3. Model: 18650AN-1500mAh

 

 

Photos

 

Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh

 

PhotosLithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh

 

Photos

Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh

 

 

Cell top

 

Cell barcode

 

|cell bottom


 

Cell physical dimension listed in Figure 1(unit: mm).

Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh

 

  1. Cell characteristics fresh cell tested at 25±2℃,standard charge unless otherwise specified 

ITEM

 

SPECIFICATION

 

Nominal capacity

 

 

1500mAh@0.2C

Nominal voltage

 

 

3.7V

Charge voltage

 

 

4.2 ±0.03V

Discharge cut-off voltage

 

 

2.75±0.03 V

charge current

 

Standard charge; 0.5C 25℃;Rapid charge:2C

 

discharge current

 

Standard discharge; 1C 25℃; Max discharge: 15C(22A)25℃(not for cycle life)

 

Max continue discharge current

 

(20A) 25℃(for cycle life)

 

Storage temperature

 

12 months : -10~45℃

3 months : -20~45℃ 

1 month : -20~60℃ 

Humidity range

 

0~90%RH (non-condensing) 

Internal resistance

 

≤20mΩ (AC Impedance, 1000 Hz)

 

 

Cell dimension

 

Height : 65.0 mm

 Diameter :18.5mm Max

Weight

 

≤44g

 

  1. Technical requirements
  2. Temperature of charge :0~45℃ 
  3. Temperature of discharge : -20~60℃

Unless otherwise specified, all tests stated according to following:

Voltage meter: The voltage tester internal resistance is ≥ 10 KW/V

Temperature meter: The precision is ≤0.5℃

 

 

Electrochemical Characteristics 

(Fresh cells, tested at 25±2℃,standard charge and discharge unless otherwise specified.

 

 

 

NO.

 

ITEM

 

CRITERION

 

 

 

 

 

 

 

 

 

 

 

5.4.1

 

 

 

 

 

 

 

Discharge rate capability

 

Test condition: Temperature : 25±2.℃

Charge: CC/CV 0.5C(750mA) 4.2V cut off current: 0.05C(75mA)

Discharge: CC variable values as the follow table; End-of-discharge Voltage: 2.75V

 

 

 

 

5.4.2

 

Charge rate capability

 

Test condition: Temperature : 25±2.℃

Charge: CC variable values as the follow table; End-of-charge Voltage: 4.2V Discharge: CC 0.5C(750mA) 2.75V

 

 

 

 

 

 

 

 

 

 

 

 

 

5.4.3

 

 

 

 

 

 

 

 

Cycle life

 

Test condition: Temperature : 25±2℃

Charge: CC/CV 1C (1.5A) 4.2V cut off current: 0.05C(75mA) Discharge: CC 13.3C(20A); End-of-discharge Voltage: 2.75V

 

Discharge capacity of 301th cycle ≥ 80% ;

 

 

 

 

 

 

5.4.4

 

 

 

High-Low temperature discharge performance

 

Test condition:

Charge: CC/CV 0.5C(750mA) 4.2V cut off current: 0.05C (75mA)

Discharge: CC 1C(1.5A); End-of-discharge Voltage: 2.75V(60℃&25℃&-20℃)

 

 

 

 

 

 

 

 

 

 

 

 

5.4.5

 

 

 

 

 

 

 

 

Storage performance

 

Test condition:

Charge: CC/CV 0.5C(750mA) 4.2V cut off current: 0.05C(75mA); stored at 25℃ for 28 days

Discharge: CC 1C(1.5 A ); End-of-discharge Voltage: 2.75V

 

 

 

Residual capacity after 28days strorgge ≥80% ; 

Original discharge capacity 

 

 

 

   

 

Recovery capacity after 28days strorgge ≥90%;

 

Test condition:

Charge: CC/CV 0.5C(750mA) 4.2V cut off current: 0.05C(75mA); stored at 60℃ for 7 days

Discharge: CC 1C(1.5A ); End-of-discharge Voltage: 2.75V

 

 

Residual capacity after 7days strorgge ≥80% ; 

 

Recovery capacity after 7days strorgge ≥90% ;

 

 

NO.

 

ITEM

 

CRITERION

 

TESTING METHOD

 

 

 

 

 

5.5.1

 

 

 

Overcharge test

 

 

 

No leakage,No flame, No fire,No explode 

Ambient Temp:25±2℃

Cell shall first be charged according to standard charge method. Then the cell is charged at 1C to 6.5V or charged at 1C for 1hr.

25±2℃

     

 

The cell is charged following the standard charge method. After charging the cell is put in the oven. And then the oven temperature will be ramped at

5℃ per minute to 130℃ and held at 130℃. When the temperature of the

cell reach 130℃, the cell is maintained in the 130℃ oven for a maximum of 30 minutes or until a fire or explosion is obtained, whichever comes

first. Record the time that the cell temperature reaches 130℃ and the time when a fire or explosion occurs.

 

 

 

 

 

 

 

 

 

 

5.5.2

 

 

 

 

 

 

130℃hot oven test

130℃ 

 

 

 

When the temperature of the cell is 130℃.

Cell must not fire or explode in 30 minutes

 

 

The cell is charged following the standard charge method. After charging the cell is put in the oven. And then the oven temperature will be ramped at

5℃ per minute to 130℃ and held at 130℃. When the temperature of the

cell reach 130℃, the cell is maintained in the 130℃ oven for a maximum of 30 minutes or until a fire or explosion is obtained, whichever comes

first. Record the time that the cell temperature reaches 130℃ and the time when a fire or explosion occurs.

 

 

 

 

 

 

 

 

 

 

 

 

5.5.3

 

 

 

 

 

 

Crush test

 

 

 

 

 

 

 

No fire,No explode

 

After charging a cell following the standard charge method, the cell shall
be crushed between two flat surfaces. The direction of the crushing force
shall be vertical to axis of the cylinder. The crushing force is to be applied
by a hydraulic ram with a 32mm diameter piston. Crushing force is
approximately 13 KN. Once the maximum pressure has been obtained it is to be released.
 
 
 
 

 

 

 

 

 

 

 

 

5.5.4

 

 

 

 

 

 

Short circuit test

 

 

 

 

 

 

 

No fire,No explode

 

 

 

Cell shall first be charged according to standard charge method, and then

cell is to be short-circuited by connecting the positive and negative

terminals of the cell with copper wire having a maximum resistance load less than 5 mΩ at 25 ℃ & 60 ℃. Monitor the cell temperature for 1hr

while testing.

 

 

 

 

 

5.5.5

 

Over discharge test

 

No fire,No explode, No leak

 

 

Cell shall first be charged according to standard charge method. Then the cell is discharged at 1C for 90min.

 

 

 

 

5.5.6

 

 

Drop test

 

No fire,No explode, Cell shall first be charged according to standard charge method, and then cell is

No leak

 

dropped 1.5m height on floor slab, with two directions.

 

   

 

 

 

5.5.7

 

Seawater immersion

 

 

 

No fire,No explode, No leak

 

Cell shall first be charged according to standard charge method, and then, immerse the battery in seawater (3.5wt% of salt) for 2 hours.

 

 

 

 

 

 

 

 

 

 

 

 

 

5.5.8

 

 

 

 

 

 

 

 

 

Thermal cycling

 

 

 

 

 

 

 

 

 

No fire,No explode, No leak

 

Cell shall first be charged according to standard charge method, and then:
1.Reduce the chamber temperature to -40℃ within 60min and maintain this
temperature for 90min.
2.Raise the chamber temperature to 25℃ within 60min.
3. Raise the chamber temperature to 85℃ within 90min and maintain this

temperature for 110min.

4. Reduce the chamber temperature to 25℃ within 70min. 5.Repeat the sequence for a further 4 cycles.

 

 
 
 
 
 

 

 

 

 

 

 

5.5.9

 

 

 

 

 

Low pressure

 

 

 

 

No fire,No explode,

 

 

 

 

Cell shall first be charged according to standard charge method, and then put the cell

No leak

 

at the pressure of 11.6Kpa for 6 hours.

 

   

 

 

 

 

 

 

5.5.10

 

 

 

 

Impact test 

 

 

 

No flame,No fire,No explode

 

Cell shall first be charged according to standard charge method,then the
battery cell was placed on a flat surface so that the longitudinal axis of the

battery cell shall be parallel with it.

A 15.8mm diameter bar is to be placed across the center of the sample. A.9.1kg weight is to be dropped from a height of 61cm on the sample.

 

 
 

 

 

 

 

 

 

 

 

 

 

5.5.11

 

 

 

 

 

 

 

 

Incineration

 

 

When subjected to the

After full charging by the standard method, each test sample cell or
battery is to be placed on a platform table having a 4-inch diameter hole in
test no part of the center covered by a screen. The screen over the hole is to be steel wire
exploding cell shall mesh having 20 openings per inch and a wire diameter of 0.017 inch An
penetrate from the eight-sided covered wire cage, 2 feet across and 1 foot high is covered
screen such that some with a metal screen is to be constructed from 0.010inch diameter wire
test or all the cell or with 16-18 wires per inch in each direction. This wire cage is placed over
  battery protrudes to the test sample. The sample is to be placed on the screen covering the
through the screen hole in the center of the hole. It is to be heated until it explodes, or until it
  is destroyed.
   
   

 


  1. Package picture 

 

Photos

 

 

Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh

Photos

 

Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh

 

Photos

 

Lithium Iron Phosphate Cylindrical Li-Ion Rechargeable Cell 3.7V 18650AN 1500mAh

 

 

Small box

 

big box

 

Pallet

 

 

  1. Shipment 

The Cell shall be shipped in voltage range of 3.6 ~ 3.9 V or in accordance with customers' requirement. The remaining capacity before charging shall be changed depending on the storage time and conditions.

 

  1. Warranty 

 

The Warranty period of cell is made according to business contract. However, even though the problem occurs within this period, Topband won’t replace a new cell for free as long as the problem is not due to the failure of Topband manufacturing process or is due to customer’s abuse or misuse.

 

Topband will not be responsible for trouble occurred by handling outside of the precautions in instructions.

 

Topband will not be responsible for trouble occurred by matching electric circuit, cell pack and charger.

 

Topband will be exempt from warrantee any defect cells during assembling after acceptance.

 

Storage and Shipment Requirement 

 

 

Item

 

 

Requirement

 

 

Storage environment

 

Short period less than 1 month

 

-20°C ~ +60°C,90%RH Max  

Long period more than 3 month

 

-10°C ~ + 45°C,90%RH Max

Recommend storage

 

-10°C ~ + 25°C ,85%RH Max

Long time storage :

If the cell is stored for a long time, the cell’s storage voltage should be 3.6-3.9V .Also, it is recommended to charge the cell every six months.

 

 